100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset

Product Details
Customization: Available
After-sales Service: Online Saves(Ols)
Warranty: 1
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Arabic
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (13)
  • 100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
  • 100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
  • 100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
  • 100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
  • 100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
  • 100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
Find Similar Products

Basic Info.

Model NO.
100GF
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit
Landuse Type of Unit
Low Noise
Excitation Mode
AC Rotating Exciter
Transport Package
Woodenbox Packaging
Specification
Depends on The Product.
Trademark
IMAQ
Origin
China
Production Capacity
3000 Units/Month

Product Description

100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
Yuchai silent style generator set
100KW static speaker series diesel generator set Diesel model: YC4A180L-D20
Generators are used in many areas of our daily life, hospitals, hotels, temporary buildings and other generators have played a certain role.
Emergency power use and characteristics of generator:
1, under normal circumstances, the emergency generator set should always be in the ready to start state, when there is insufficient power supply, there is an interruption state. Emergency power supply of generator set should be started immediately. After starting for a certain time, the emergency generator set should be able to continue carrying for about a certain time (adjustable) until the mains power supply is stable, and then it is converted to the mains power supply with load.
2, There should be a mechanical interlock device between the emergency generator set and the power system to prevent parallel operation to ensure the safety of electricity consumption.

 
3, the emergency diesel generator self-start success rate is not less than 99%, the unit self-start failure, should be able to send an alarm signal, the unit should be able to operate locally and in the compartment, provide the remote control panel, the unit self-start signal is provided by the load low voltage main input voltage relay combination.
4, the emergency generator set should have the characteristics of fast start, strong ability to withstand sudden load, reliable operation, good speed regulation, low failure rate, low noise, low vibration, low pollution, small size, light weight, easy maintenance and so on.
5, the generator set maintenance manufacturer reminds the emergency generator set should have an independent fuel storage room to ensure a certain amount of fuel and fire safety measures.
6, the important components of the emergency generator set, such as the engine, generator, generator controller, etc., should use reliable quality and advanced technology products, and provide their origin, manufacturers and corresponding technical instructions when bidding.
 
100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
7. The emergency generator set should provide an outlet distribution cabinet on the spot and configure the frame removable circuit breaker. Generator should be equipped with short circuit, overload, grounding, overvoltage, undervoltage, reverse power fault protection devices

The noise of silent diesel generator sets can be divided into the following parts:
(1) exhaust noise (2) mechanical noise (3) combustion noise (4) cooling fan (5) intake noise (6) generator noise
According to the distribution of the noise source and the characteristics of the noise, the generator supplier adopts the control technology of sound insulation, sound absorption and noise reduction to deal with the noise of different parts respectively, so as to achieve the noise reduction effect. When the unit is placed inside the box, due to sound insulation technology, sound absorption and other technologies effectively prevent the noise from spreading outwards, the noise source is controlled inside the box, thereby reducing its impact on the outside world. Sound insulation technology is to use the sound insulation body to change the propagation direction of some sound waves (reflection, refraction), so that the sound wave energy that penetrates the object is weakened, thus reducing the noise on the other side of the sound insulation body.

 

Parameters:
Diesel generator set data
Type 100GF Unit power (KVA/KW) 125/100
Output voltage (V) 400/230 Rated output current (A) 181
Wiring mode Three-phase four-wire Power factor 0.8(lag)
Starting mode 24V DC Starting Frequency (Hz) 50
Unit weight (kg) 1300 Unit size (L*W*H) 2400×750×1400mm
Diesel engine data
Manufacturer Guangxi Yuchai Model YC4A180L-D20
Rated speed (Rpm) 1500 Maximum engine power (KW) 132
Number of cylinders 4 Cylinders are arranged straight line
Cylinder diameter × stroke (mm) 108×132 Displacement (L) 4.837
Intake mode Supercharged intercooling Compression ratio 17.5:1
Fuel China 0# light diesel 100% load fuel consumption (G/KW.h) 218
Lubricating oil specification 15W/40CD Lubricating oil consumption (L/h) 0.5% fuel consumption
Starting mode Electric starting Oil capacity (L) 13
The engine cooling method meets the ambient temperature of 40ºC radiator, belt driven cooling fan, with fan safety guard
Generator data
Model DLS-100 Efficiency (%) 80
Power (KVA/KW) 125/100 Protection class IP23
Insulation class H Steady-state voltage adjustment rate is better than ±1%
No-load voltage adjustment range ≥±5% Voltage control mode AVR
 
100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
 
 
100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset
100kw Generator Open Silent Soundproof Diesel Power Electric Generator Set Genset



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier